All defects are from reports produced by/for Taylor Wimpey - Taylor Wimpey are not disputing that the defects exist - just not fixing them! Every day a new defect - think of it as an Advent Calendar of building defects (although there are a few more than 24...)


6. External wall build-up was not as the drawings. Where as-built drawings indicated that make-up was to consist of 200mm full fill Rockwool, investigation revealed 100mm had been provided and in some areas was missing entirely.

TWCLDefects's tweet image. 6. External wall build-up was not as the drawings. Where as-built drawings indicated that make-up was to consist of 200mm full fill Rockwool, investigation revealed 100mm had been provided and in some areas was missing entirely.

5. Unsealed holes compromising fire-resistant walls #BuildingSafetyCrisis #FireSafety

TWCLDefects's tweet image. 5. Unsealed holes compromising fire-resistant walls #BuildingSafetyCrisis #FireSafety

4. Mechanical ventilation unit poorly installed with hoses kinked to an extent that the unit’s suction fan is put under strain and failed.

TWCLDefects's tweet image. 4. Mechanical ventilation unit poorly installed with hoses kinked to an extent that the unit’s suction fan is put under strain and failed.

Taylor Wimpey Defects reposted

Here is the breakdown 👇 If your council has been allocated funding, get in touch with them and ask what this funding will be used for. 2/2 #BuildingSafetyCrisis

EOCS_Official's tweet image. Here is the breakdown 👇

If your council has been allocated funding, get in touch with them and ask what this funding will be used for. 

2/2

#BuildingSafetyCrisis
EOCS_Official's tweet image. Here is the breakdown 👇

If your council has been allocated funding, get in touch with them and ask what this funding will be used for. 

2/2

#BuildingSafetyCrisis

3. Soil stacks not fire stopped through slabs between apartments. #BuildingSafetyCrisis

TWCLDefects's tweet image. 3. Soil stacks not fire stopped through slabs between apartments. #BuildingSafetyCrisis

2. Fire stopping missing at points where the MVHR ducting pass through compartment walls. Some have been sealed with a white mastic instead of HPE mastic (which is black in colour).


1. Penetrations made through party walls without any fire protection, thus breaching the fire compartmentation required.